Parameter naming
Specify rules for naming Simulink.Parameter and
mpt.Parameter objects in generated code
Model Configuration Pane: Code Generation / Identifiers
Description
Specify rules for naming Simulink.Parameter and
mpt.Parameter data objects in generated code.
Dependencies
This parameter appears only for ERT-based targets.
This parameter requires an Embedded Coder® license when generating code.
Setting this parameter to
Custom M-functionenables M-function.This parameter must be the same for top-level and referenced models.
Settings
None (default) | Force upper case | Force lower case | Custom M-functionNoneDoes not change parameter names when creating corresponding identifiers in generated code. Parameter identifiers in the generated code match the parameter names that appear in the model.
Force upper caseUses uppercase characters when creating identifiers for parameter names in the generated code.
Force lower caseUses lowercase characters when creating identifiers for parameter names in the generated code.
Custom M-functionUses the MATLAB® function specified with the M-function parameter to create identifiers for parameter names in the generated code.
Recommended Settings
| Application | Setting |
|---|---|
| Debugging | No impact |
| Traceability | Force upper case |
| Efficiency | No impact |
| Safety precaution | No impact |
Programmatic Use
Parameter: ParamNamingRule |
| Type: character vector |
Value: None | UpperCase | LowerCase | Custom |
Default: None |
Version History