HTTP/1.1 200 OKServer: GlassFish Server Open Source Edition 4.1.1 X-Powered-By: Servlet/3.1 JSP/2.3 (GlassFish Server Open Source Edition 4.1.1 Java/Oracle Corporation/1.8) Set-Cookie: JSESSIONID=0fc4683b156f312493d00b8c7a65; Path=/; Secure; HttpOnly Set-Cookie: MW_Doc_Template=WEB||||||||||; Path=/help Cache-Control: no-store, no-cache, must-revalidate, post-check=0, pre-check=0 Pragma: no-cache Expires: Tue, 03 Dec 2019 08:34:08 EST Content-Type: text/html;charset=utf-8 Date: Sat, 05 Dec 2020 03:40:07 GMT Transfer-Encoding: chunked f766 Specify logical address of VXI instrument - MATLAB - MathWorks Australia
Main Content

LogicalAddress

Specify logical address of VXI instrument

Description

For VISA-VXI and VISA-GPIB-VXI objects, you configure LogicalAddress to be the logical address of the VXI instrument. You must include the logical address as part of the resource name during object creation using the visa function.

The Name and RsrcName properties are automatically updated to reflect the LogicalAddress value.

You can configure LogicalAddress only when the object is disconnected from the instrument. You disconnect a connected object with the fclose function. A disconnected object has a Status property value of closed.

Characteristics

Usage

VISA-VXI, VISA-GPIB-VXI

Read only

While open

Data type

Double

Values

The value is defined when the instrument object is created.

Examples

This example creates a VISA-VXI object associated with chassis 4 and logical address 1, and then returns the logical address.

vv = visa('keysight','VXI4::1::INSTR');
vv.LogicalAddress
ans =
     1