Main Content

Transfer Fcn Real Zero

Implement discrete-time transfer function that has real zero and no pole

  • Transfer Fcn Real Zero block

Libraries:
Simulink / Discrete

Description

The Transfer Fcn Real Zero block implements a discrete-time transfer function that has a real zero and effectively no pole.

Ports

Input

expand all

Input signal to the discrete-time transfer function algorithm.

Data Types: single | double | int8 | int16 | int32 | int64 | uint8 | uint16 | uint32 | uint64 | fixed point

Output

expand all

Output signal that is the discrete-time transfer function with a real zero and effectively no pole of the input signal.

Data Types: single | double | int8 | int16 | int32 | int64 | uint8 | uint16 | uint32 | uint64 | fixed point

Parameters

expand all

Specify the zero in the Z plane.

Programmatic Use

Block Parameter: ZeroZ
Type: character vector
Value: real scalar
Default: '0.75'

Specify the initial condition for the previous input.

Programmatic Use

Block Parameter: ICPrevInput
Type: character vector
Value: real scalar
Default: '0.0'

Specify whether the block performs sample- or frame-based processing:

  • Columns as channels (frame based) — Treat each column of the input as a separate channel (frame-based processing).

    Note

    Frame-based processing requires a DSP System Toolbox™ license.

    For more information, see Sample- and Frame-Based Concepts (DSP System Toolbox).

  • Elements as channels (sample based) — Treat each element of the input as a separate channel (sample-based processing).

Use Input processing to specify whether the block performs sample- or frame-based processing. For more information about these two processing modes, see Sample- and Frame-Based Concepts (DSP System Toolbox).

Programmatic Use

Block Parameter: InputProcessing
Type: character vector
Values: 'Columns as channels (frame based)' | 'Elements as channels (sample based)'
Default: 'Elements as channels (sample based)'

Specify the rounding mode for fixed-point operations. For more information, see Rounding Modes (Fixed-Point Designer).

Block parameters always round to the nearest representable value. To control the rounding of a block parameter, enter an expression using a MATLAB® rounding function into the mask field.

Programmatic Use

To set the block parameter value programmatically, use the set_param function.

Parameter: RndMeth
Values: 'Floor' (default) | 'Ceiling' | 'Convergent' | 'Nearest' | 'Round' | 'Simplest' | 'Zero'

When you select this check box, overflows saturate to the maximum or minimum value that the data type can represent. Otherwise, overflows wrap.

When you select this check box, saturation applies to every internal operation on the block, not just the output or result. In general, the code generation process can detect when overflow is not possible. In this case, the code generator does not produce saturation code.

Programmatic Use

Block Parameter: DoSatur
Type: character vector
Values: 'off' | 'on'
Default: 'off'

Block Characteristics

Data Types

Booleana | double | fixed point | integer | single

Direct Feedthrough

no

Multidimensional Signals

no

Variable-Size Signals

yes

Zero-Crossing Detection

no

a This block is not recommended for use with Boolean signals.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

PLC Code Generation
Generate Structured Text code using Simulink® PLC Coder™.

Fixed-Point Conversion
Design and simulate fixed-point systems using Fixed-Point Designer™.

Version History

Introduced before R2006a