Troubleshoot S-Function Parameters Not Visible in Simulink Real-Time Explorer
The parameters for the s-functions in a real-time application do not appear in the Parameters tab in Simulink® Real-Time™ Explorer.
What This Issue Means
Simulink Real-Time Explorer does not display S-function parameters that are defined by using a literal expression. This approach in explorer prevents the display of many parameters that are used by hardware drivers. The Block Parameters dialog box figure shows a parameter that is defined by using the literal expression 5.
Try This Workaround
To display an S-function parameter in the Parameters tab in
Simulink
Real-Time Explorer, define a variable in the model workspace, then use the variable
instead of a literal expression in the S-function parameter. For the S-function
parameter in the figure, you could define a variable gainParam
with a
value 5
, then define the S-function parameter as:
'++',gainParam,'SumTimesGain'