TI Radar Toolbox with DCA1000EVM Connection - Continuous error occurs when attempting to connect with an Ethernet cable

8 views (last 30 days)
I failed to connect to the DCA1000EVM in the TI Radar Toolbox.
This is our hardware setting
we are using awr1642boost with dca1000evm capture board
I have provided a screenshot of the device manager and Ethernet IP adress. All networks except for Ethernet have been disconnected.
This is the result of the 'ipconfig' command in CMD
This is the inbound and outbound rule configuration.
How can we solve this error??

Answers (1)

Walter Roberson
Walter Roberson on 29 Nov 2024
Edited: Walter Roberson on 30 Nov 2024
Your ipconfig shows that you have configured the local IP address of the second interface as 192.168.33.30 . However, 192.168.33.30 needs to be the address of the connected device, not the local address of the second interface. You need to configre the second interface address as something else in the 192.168.33.x range (excluding 192.168.33.255). It is probably best to configure the second interface to be 192.168.33.1
  4 Comments
정빈
정빈 on 4 Dec 2024
I wanted to take a moment to sincerely thank you for your help and support. Your guidance has been invaluable, and I truly appreciate the time and effort you've invested in assisting me. I am very grateful for your generosity and expertise.