Configure AUTOSAR CompuMethods
AUTOSAR software components use computation methods (CompuMethods) to convert between the internal values and physical representation of AUTOSAR data. Common uses for CompuMethods are linear data scaling and calibration and measurement.
Embedded Coder® imports AUTOSAR CompuMethods described in ARXML code and preserves them across round-trips between an AUTOSAR authoring tool (AAT) and Simulink®. In Simulink, you can modify imported CompuMethods or create and configure new CompuMethods.
This topic provides examples of configuring AUTOSAR CompuMethods in Simulink.
Modify Linear Scaling for SCALE_LINEAR_AND_TEXTTABLE CompuMethod
Configure Rational Function CompuMethod for Dual-Scaled Parameter
Configure AUTOSAR CompuMethod Properties
You can configure AUTOSAR CompuMethod properties in your model, either graphically or programmatically. The CompuMethod properties you can modify include name, category, unit, display format, AUTOSAR package, and Simulink data types.
To configure a CompuMethod using the graphical interface, open the AUTOSAR Dictionary and select the CompuMethods view. This view displays the modifiable CompuMethods in the model, whether imported from ARXML code or created in Simulink.
Select a CompuMethod and edit the available fields.
Name — Specify name text
Category — Select
Identical
,Linear
,RatFunc
,TextTable
, orLinearAndTextTable
(see CompuMethod Categories for Data Types)Unit — Select from units available in the model
DisplayFormat — Optionally specify format to be used by calibration and measurement tools to display the data. Use an ANSI® C
printf
format specifier string. For example,%2.1d
specifies a signed decimal number, with a minimum width of two characters and maximum precision of one digit. The string produces a displayed value such as 12.2. For more information about constructing a format specifier string, see Configure DisplayFormat.Package — Specify path of AUTOSAR package to be generated for CompuMethods
Simulink DataTypes — Specify list of Simulink data types that reference the CompuMethod
To modify the AUTOSAR package for a CompuMethod, you can do either of the following:
Enter a package path in the Package parameter field.
To open the AUTOSAR Package Browser, click the button to the right of the Package field. Use the browser to navigate to an existing package or create and select a package. When you select a package in the browser and click Apply, the CompuMethod Package parameter value is updated with your selection. For more information about the AUTOSAR Package Browser, see Configure AUTOSAR Package for Component, Interface, CompuMethod, or SwAddrMethod.
To associate a CompuMethod with a Simulink data type used in the model, select a CompuMethod and click the
Add button to the right of Simulink
DataTypes. This action opens a dialog box with a list of available
data types. In the list of values, select a Simulink.NumericType
or
Simulink.AliasType
, or enter the name of a Simulink enumerated type. To add the type to the Simulink
DataTypes list, click OK.
To set the Simulink DataTypes property programmatically, open
the model and use an AUTOSAR property set
function call similar
to the following:
arProps=autosar.api.getAUTOSARProperties('cmSpeed'); set(arProps,'/pkg/CompuMethods/RpmCm','SlDataTypes',{'SpeedRpmAdt'}) sltypes=get(arProps,'/pkg/CompuMethods/RpmCm', 'SlDataTypes')
sltypes = 'SpeedRpmAdt'
Create AUTOSAR CompuMethods
You can create AUTOSAR CompuMethods in your model, either graphically or
programmatically. To create an AUTOSAR CompuMethod using the graphical interface,
open the AUTOSAR Dictionary and select the CompuMethods view.
To open the Add CompuMethod dialog box, click the Add button
. Configure the initial properties for the
CompuMethod, such as name, category, unit, display format for calibration, AUTOSAR
package to generate, and associated Simulink data type. When you click OK, the CompuMethods
view in the AUTOSAR Dictionary is updated with the new CompuMethod.
When you generate code, the exported ARXML code contains the CompuMethod definition and references to it.
Configure CompuMethod Direction for Linear Functions
For designs originated in Simulink, you can control properties for an exported
CompuMethod
, including the direction of
CompuMethod
conversion
between internal and physical representations of a value. Using either the AUTOSAR
Dictionary or the AUTOSAR property set
function, you can
specify one of the following CompuMethod
direction values:
InternalToPhys
(default) — GenerateCompuMethod
sections for conversion of internal values into their physical representations.PhysToInternal
— GenerateCompuMethod
sections for conversion of physical values into their internal representations.Bidirectional
— GenerateCompuMethod
sections for both internal-to-physical and physical-to-internal conversion directions.
To specify CompuMethod
direction in the MATLAB® Command Window, use an AUTOSAR property set
function call similar to the following:
hModel = 'autosar_swc_expfcns'; openExample(hModel); arProps=autosar.api.getAUTOSARProperties(hModel); set(arProps,'XmlOptions','CompuMethodDirection','Bidirectional'); get(arProps,'XmlOptions','CompuMethodDirection')
To specify CompuMethod
direction in the AUTOSAR Dictionary,
select XML Options. Select a value for parameter
CompuMethod Direction. Click
Apply.
When you generate code for your model, the CompuMethods in the exported ARXML code
contain the requested directional sections. For example, here is a CompuMethod
generated with the CompuMethod direction set to
Bidirectional
.
<COMPU-METHOD UUID="..."> <SHORT-NAME>COMPU_EngSpdValue</SHORT-NAME> <CATEGORY>LINEAR</CATEGORY> <COMPU-INTERNAL-TO-PHYS> <COMPU-SCALES> <COMPU-SCALE> <SHORT-LABEL>intToPhys</SHORT-LABEL> <LOWER-LIMIT INTERVAL-TYPE="CLOSED">0</LOWER-LIMIT> <UPPER-LIMIT INTERVAL-TYPE="CLOSED">24000</UPPER-LIMIT> <COMPU-RATIONAL-COEFFS> <COMPU-NUMERATOR> <V>0</V> <V>1</V> </COMPU-NUMERATOR> <COMPU-DENOMINATOR> <V>8</V> </COMPU-DENOMINATOR> </COMPU-RATIONAL-COEFFS> </COMPU-SCALE> </COMPU-SCALES> </COMPU-INTERNAL-TO-PHYS> <COMPU-PHYS-TO-INTERNAL> <COMPU-SCALES> <COMPU-SCALE> <SHORT-LABEL>physToInt</SHORT-LABEL> <LOWER-LIMIT INTERVAL-TYPE="CLOSED">0</LOWER-LIMIT> <UPPER-LIMIT INTERVAL-TYPE="CLOSED">3000</UPPER-LIMIT> <COMPU-RATIONAL-COEFFS> <COMPU-NUMERATOR> <V>0</V> <V>8</V> </COMPU-NUMERATOR> <COMPU-DENOMINATOR> <V>1</V> </COMPU-DENOMINATOR> </COMPU-RATIONAL-COEFFS> </COMPU-SCALE> </COMPU-SCALES> </COMPU-PHYS-TO-INTERNAL> </COMPU-METHOD>
Note
CompuMethods of category TEXTTABLE, which are generated for Boolean or
enumerated data types, use only InternalToPhys
, regardless of
the direction parameter setting.
Export CompuMethod Unit References
The ARXML importer preserves unit and physical dimension information found in imported CompuMethods. The software preserves CompuMethod unit and physical dimension information across round-trips between an AUTOSAR authoring tool (AAT) and Simulink.
For designs originated in Simulink, the exporter generates a unit reference for each
CompuMethod
. By convention, each
CompuMethod
references a unit named
NoUnit
. For example, here is a Boolean data type
CompuMethod
and the unit it references.
<COMPU-METHOD UUID="..."> <SHORT-NAME>COMPU_Boolean</SHORT-NAME> <CATEGORY>TEXTTABLE</CATEGORY> <UNIT-REF DEST="UNIT">/mymodel_pkg/mymodel_dt/NoUnit</UNIT-REF> ... </COMPU-METHOD> <UNIT UUID="..."> <SHORT-NAME>NoUnit</SHORT-NAME> <FACTOR-SI-TO-UNIT>1</FACTOR-SI-TO-UNIT> <OFFSET-SI-TO-UNIT>0</OFFSET-SI-TO-UNIT> </UNIT>
Providing a unit for each exported CompuMethod
helps support
calibration and measurement tool use of exported AUTOSAR data.
Modify Linear Scaling for SCALE_LINEAR_AND_TEXTTABLE CompuMethod
You can import and export an AUTOSAR CompuMethod that uses LINEAR and TEXTTABLE
scaling. Importing application data types that reference CompuMethods of category
SCALE_LINEAR_AND_TEXTTABLE creates Simulink.NumericType
or
Simulink.AliasType
data objects in the Simulink workspace. In Simulink, you can modify the LINEAR scaling for the CompuMethods. The TEXTTABLE
scaling is read-only.
For example, here is a CompuMethod with one LINEAR scale and two TEXTTABLE scales.
When you import the CompuMethod into a model, the importer creates a
Simulink.NumericType
with linear scaling. To modify the
linear scaling, open the Simulink.NumericType
data object and
modify its fields.
For read-only access to the TEXTTABLE scaling information, use AUTOSAR property
get
function calls similar to the following:
>> arProps=autosar.api.getAUTOSARProperties('mySWC'); >> % Get literals for COMPU_myType TEXTTABLE scales >> get(arProps,'/simple_ar_package/simple_ar_dt/COMPU_myType','CellOfEnums') ans = 'SensorError' 'SignalNotAvailable' >> % Get internal values for COMPU_myType TEXTTABLE scales >> get(arProps,'/simple_ar_package/simple_ar_dt/COMPU_myType','IntValues') ans = 350 351
Configure Rational Function CompuMethod for Dual-Scaled Parameter
For an AUTOSAR dual-scaled parameter, which stores two scaled values of the same
physical value, the software generates the CompuMethod
category
RAT_FUNC
. The computation method can be a first-order
rational function.
To configure and generate a dual-scaled parameter:
Open an AUTOSAR model. For the purposes of this example, create a Constant block from which to reference an AUTOSAR dual-scaled parameter. In the model, connect the Constant block to a Simulink outport.
Open the Model Data Editor (on the Modeling tab, click Model Data Editor) and select the Parameters tab. Find the parameter entry for the Constant block. Use the Value column to reference the name of a dual-scaled parameter. This example uses the parameter name
T1Rec
.Create the
T1Rec
data object. In the Model Data Editor, to the right of the valueT1Rec
, click the action buttonand select Create.
In the Create New Data dialog box, set Value to
AUTOSAR.DualScaledParameter
and click Create. AnAUTOSAR.DualScaledParameter
data object appears in the base workspace. The dual-scaled parameter property dialog box opens.Configure the attributes of the dual-scaled parameter
T1Rec
. Execute the following MATLAB code. The code sets up a conversion from an internal calibration time value to a physical frequency (time reciprocal) value.% Conversion from Time to Frequency % F = 1/T % In Other Words F = (0*T + 1)/(1*T+0); T1Rec.CompuMethodName = 'CM3'; %Specify AUTOSAR CompuMethod name T1Rec.DataType ='fixdt(1,32,0.01,0)'; T1Rec.CalToMainCompuNumerator=1; T1Rec.CalToMainCompuDenominator=[1 0]; T1Rec.CalibrationMin = 0.001; T1Rec.CalibrationMax = 1.0; T1Rec.CalibrationValue = 0.1500; T1Rec.CoderInfo.StorageClass = 'Custom'; T1Rec.CoderInfo.Identifier = ''; T1Rec.CoderInfo.CustomStorageClass = 'InternalCalPrm'; T1Rec.CoderInfo.CustomAttributes.PerInstanceBehavior =... 'Parameter shared by all instances of the Software Component'; T1Rec.Description = ''; % T1Rec.Min = []; % T1Rec.Max = []; T1Rec.Unit = ''; T1Rec.CalibrationDocUnits = 'm/s²';
Inspect the property dialog box for the dual-scaled parameter
T1Rec
. Here are the main attributes set by the MATLAB code.Here are the calibration attributes set by the MATLAB code.
If
CompuMethod
direction is not already set to bidirectional in the AUTOSAR properties, use the AUTOSAR Dictionary, XML Options view, to set it.Generate code from the model.
When you generate code from the model, the ARXML exporter generates a
CompuMethod
of category RAT_FUNC
.
<COMPU-METHOD UUID="..."> <SHORT-NAME>CM3</SHORT-NAME> <CATEGORY>RAT_FUNC</CATEGORY> <UNIT-REF DEST="UNIT">/mymodel_pkg/mymodel_dt/m_s_</UNIT-REF> <COMPU-INTERNAL-TO-PHYS> <COMPU-SCALES> <COMPU-SCALE> <COMPU-RATIONAL-COEFFS> <COMPU-NUMERATOR> <V>-100</V> </COMPU-NUMERATOR> <COMPU-DENOMINATOR> <V>0</V> <V>-1</V> </COMPU-DENOMINATOR> </COMPU-RATIONAL-COEFFS> </COMPU-SCALE> </COMPU-SCALES> </COMPU-INTERNAL-TO-PHYS> <COMPU-PHYS-TO-INTERNAL> <COMPU-SCALES> <COMPU-SCALE> <COMPU-RATIONAL-COEFFS> <COMPU-NUMERATOR> <V>100</V> </COMPU-NUMERATOR> <COMPU-DENOMINATOR> <V>0</V> <V>1</V> </COMPU-DENOMINATOR> </COMPU-RATIONAL-COEFFS> </COMPU-SCALE> </COMPU-SCALES> </COMPU-PHYS-TO-INTERNAL> </COMPU-METHOD>
The CompuMethod
is referenced from the application data type
generated for T1Rec
.
<APPLICATION-PRIMITIVE-DATA-TYPE UUID="..."> <SHORT-NAME>T1Rec_DualScaled</SHORT-NAME> <CATEGORY>VALUE</CATEGORY> <SW-DATA-DEF-PROPS> <SW-DATA-DEF-PROPS-VARIANTS> <SW-DATA-DEF-PROPS-CONDITIONAL> <SW-CALIBRATION-ACCESS>READ-WRITE</SW-CALIBRATION-ACCESS> <COMPU-METHOD-REF DEST="COMPU-METHOD">/mymodel_pkg/mymodel_dt/CM3</COMPU-METHOD-REF> <DATA-CONSTR-REF DEST="DATA-CONSTR">/mymodel_pkg/mymodel_dt/ApplDataTypes/ DataConstrs/DC_T1Rec_DualScaled</DATA-CONSTR-REF> </SW-DATA-DEF-PROPS-CONDITIONAL> </SW-DATA-DEF-PROPS-VARIANTS> </SW-DATA-DEF-PROPS> </APPLICATION-PRIMITIVE-DATA-TYPE>
The application data type T1Rec_DualScaled
is referenced from
the parameter data prototype generated for T1Rec
.
<PARAMETER-DATA-PROTOTYPE UUID="..."> <SHORT-NAME>T1Rec</SHORT-NAME> <SW-DATA-DEF-PROPS> <SW-DATA-DEF-PROPS-VARIANTS> <SW-DATA-DEF-PROPS-CONDITIONAL> <SW-CALIBRATION-ACCESS>READ-WRITE</SW-CALIBRATION-ACCESS> <SW-IMPL-POLICY>STANDARD</SW-IMPL-POLICY> </SW-DATA-DEF-PROPS-CONDITIONAL> </SW-DATA-DEF-PROPS-VARIANTS> </SW-DATA-DEF-PROPS> <TYPE-TREF DEST="APPLICATION-PRIMITIVE-DATA-TYPE">/mymodel_pkg/mymodel_dt/ApplDataTypes/ T1Rec_DualScaled</TYPE-TREF> ... </PARAMETER-DATA-PROTOTYPE>