Pressure Source (TL)
Generate constant or time-varying pressure differential
Libraries:
Simscape /
Foundation Library /
Thermal Liquid /
Sources
Description
The Pressure Source (TL) block represents an ideal mechanical energy source in a thermal liquid network. The source can maintain the specified pressure differential across its ports regardless of the flow rate through the source. There is no flow resistance and no heat exchange with the environment.
Ports A and B represent the source inlet and outlet. The input physical signal at port P specifies the pressure differential. Alternatively, you can specify a constant pressure differential as a block parameter. A positive pressure differential causes the pressure at port B to be greater than the pressure at port A.
The energy balance at the source is a function of the energy flow rates through ports A and B and the work done on the fluid:
where:
ϕA is the energy flow rate into the source through port A.
ϕB is the energy flow rate into the source through port B.
ϕwork is the isentropic work done on the fluid.
The isentropic work term is
where:
ϕwork is the isentropic work done on the thermal liquid.
pA is the pressure at port A.
pB is the pressure at port B.
ρavg is the average liquid density,
Assumptions and Limitations
There are no irreversible losses.