Check safety-related diagnostic settings for compatibility

mathworks.hism.hisl_0301

Dependencies: Simulink® Check™

Usage: High-Integrity System Modeling

Guideline: hisl_0301: Configuration Parameters > Diagnostics > Compatibility

Description

Use this check to verify that the model configuration uses optimal parameter settings that apply to compatibility when generating code for a safety-related application.

Recommended Actions and Results

Review the violations that are flagged by the check and the recommended action for fixing the issue. After applying the changes, save the model and rerun the check analysis.

Modeling ConditionRecommended Action
The diagnostic that detects when a block has not been upgraded to use features of the current release is set to none or warning. An S-function written for an earlier version might not be compatible with the current version and generated code could operate incorrectly.Set model configuration parameter S-function upgrades needed to error.

Capabilities and Limitations

  • Does not run on library models

  • Does not allow exclusions of blocks or charts

  • Does not require model compilation

Version History