Other Output
Write to one or more output channels not handled by specific blocks
Libraries:
Simulink Desktop Real-Time
Description
The Other Output block connects to and write to hardware sinks requiring specialized driver support that other Simulink® Desktop Real-Time™ output blocks do not provide. The Other Output block is rarely used and only for a few drivers. For details, see the documentation for the driver that you intend to use.
If none of the available blocks, including Other Output, provide what you need, you can create your own I/O blocks to work with Simulink Desktop Real-Time applications. For more information, see Integrate C Code in Custom S-Functions.
Examples
Packet Input/Output
Transfer data through UDP communication protocol using binary encoding.
CAN Input/Output with Vehicle Network Toolbox
Transfer data through CAN bus by using the CAN Pack and CAN Unpack blocks available in Vehicle Network Toolbox™ block library.
Ports
Input
Data — Data to write to output channels
vector
The data type and range of the input value depend upon the capabilities of the board.
Data Types: single
| double
| int8
| uint8
| int16
| uint16
| int32
| uint32
Output
Missed Ticks — Missed tick count (optional)
double
In Connected IO mode, returns the number of timer ticks that your model lags behind the real-time kernel. When the model lags by more than Maximum missed ticks, the software reports an error and simulation stops.
Dependency
When you select Show “Missed Ticks” port, this port is visible.
Data Types: double
Parameters
Install new board — Register a board
< no board selected >
(default)
When you click Install new board, the software displays a list of manufacturers of supported boards. When you select a manufacturer, the software displays a list of boards available from that manufacturer. When you select a board, the software adds the board to the list of registered boards and makes that board the current board.
By default, the initial selection in the list of registered boards is <
no board selected >
.
For more information about driver support for I/O boards, see Hardware Support from Simulink Desktop Real-Time.
Dependency
When you select a board in the list of registered boards, the Delete current board and Board setup buttons are available.
Programmatic Use
Block Parameter:
DrvName |
Delete current board — Delete the current board
(button)
To delete the current board, click this button. The initial
selection of the list of registered boards changes to <
no board selected >
.
Dependency
To activate this parameter, select a board in the list of registered boards.
When you delete the current board, the Delete current board and Board setup buttons are no longer available.
Programmatic Use
Block Parameter:
DrvName |
Board setup — Set up the board
(button)
To set up the board, click this button.
A board-specific dialog box opens to set up the board. For more information, see the board manufacturer documentation.
Dependency
To activate this parameter, select a board in the list of registered boards.
To deactivate this parameter, click Delete current board.
Programmatic Use
Block Parameter:
DrvAddress |
Block Parameter:
DrvOptions |
Sample time — Sample time of block
0.1
(default) | double
Enter a value, in seconds, that represents how frequently you want the block to execute and interact with the I/O hardware. The block synchronizes your model with the real-time clock at this sample rate.
If you are using a fixed-step solver, enter the value that you entered as the Fixed step size configuration parameter or an integer multiple of that value.
Programmatic Use
Block Parameter:
SampleTime |
Maximum missed ticks — Number of timer ticks by which your model can trail the kernel
10
(default) | integer
In Connected IO mode, enter the number of timer ticks that your model can lag behind the real-time kernel. When the model lags behind by this number or fewer timer ticks, the software assumes that the lag is temporary. It allows the model to catch up, even if the model misses some ticks. When the model lags by more than this number, the software reports an error and simulation stops.
In Run in Kernel mode, the software ignores this value.
Programmatic Use
Block
Parameter:
MaxMissedTicks |
Show “Missed Ticks” port — Send number of missed ticks to port Missed Ticks
'off'
(default) | 'on'
In Connected IO mode, select this check box to send the number of missed
ticks to output port Missed Ticks
.
In Run in Kernel mode, the Missed Ticks
port is
zero.
Programmatic Use
Block Parameter:
ShowMissedTicks |
Yield CPU when waiting — Yield CPU while kernel waits for hardware
'off'
(default) | 'on'
In Connected IO mode, select this check box to grant other programs more CPU time while the kernel waits for a response from the hardware.
In Run in Kernel mode, the software ignores this value.
Programmatic Use
Block Parameter:
YieldWhenWaiting |
Output channels — Channel vector that selects other output channels
1
(default) | vector
Enter a channel vector that selects the other output channels that you are using on this board. The vector can be any valid MATLAB® vector form. For example, to select the first two other output channels, enter:
[1,2]
or
[1:2]
Programmatic Use
Block Parameter:
Channels |
Optional parameters — Specify optional parameters that the driver requires
0
(default) | vector
See the manufacturer data sheet for the required values.
Programmatic Use
Block Parameter:
OptParam |
Initial value — Specify the value that the channel generates before execution starts
vector
Enter the initial value for each output channel that you entered in the Output channels box.
Programmatic Use
Block Parameter:
InitialValue |
Final value — Specify the value that the channel generates after execution ends
vector
Enter the final value for each output channel that you entered in the Output channels box.
Programmatic Use
Block Parameter:
FinalValue |
Version History
Introduced before R2006aR2024b: Update to blocks with port names
In R2024b, when you enable optional ports, such as Show "Missed Ticks" port, these Simulink Desktop Real-Time block ports appear with labels.
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)
Asia Pacific
- Australia (English)
- India (English)
- New Zealand (English)
- 中国
- 日本Japanese (日本語)
- 한국Korean (한국어)