Main Content

CAN FD Pack

Pack individual signals into message for CAN FD bus

  • CAN FD Pack block

Libraries:
Vehicle Network Toolbox / CAN FD Communication
C2000 Microcontroller Blockset / Target Communication
Simulink Real-Time / CAN / CAN-FD MSG blocks

Description

The CAN FD Pack block loads signal data into a message at specified intervals during the simulation.

To use this block, you also need a license for Simulink® software.

The CAN FD Pack block supports:

  • The use of Simulink accelerator mode. Using this feature, you can speed up the execution of Simulink models. For more information, see Acceleration.

Tip

  • To work with J1939 messages, use the blocks in the J1939 Communication block library instead of this block. See J1939.

Ports

Input

expand all

The CAN FD Pack block has one input port by default. The number of block inputs is dynamic and depends on the number of signals that you specify for the block. For example, if your message has four signals, the block can have four input ports.

The block supports the following input signal data types: single, double, int8, int16, int32, int64, uint8, uint16, uint32, uint64, and boolean. The block does not support fixed-point data types.

Tip

Even if you have a zero-length message with no signals, you still must provide dummy data to the input port, for purposes of defining the sample time. In this case, the data value itself is ignored.

Output

expand all

This block has one output port, Msg. The CAN FD Pack block takes the specified input signals and packs them into a CAN FD message, output as a Simulink CAN_FD_MESSAGE_BUS signal. For more information on Simulink bus objects, see Composite Interfaces.

Parameters

expand all

  • raw data: Input data as a uint8 vector array. If you select this option, you only specify the message fields. all other signal parameter fields are unavailable. This option opens only one input port on your block.

    The conversion formula is:

    raw_value = (physical_value - Offset) / Factor
    where physical_value is the original value of the signal and raw_value is the packed signal value.

  • manually specified signals: Allows you to specify data signal definitions. If you select this option, use the Signals table to create your signals. The number of block inputs depends on the number of signals you specify.

  • CANdb specified signals: Allows you to specify a CAN database file that contains message and signal definitions. If you select this option, select a CANdb file. The number of block inputs depends on the number of signals specified in the CANdb file for the selected message.

Programmatic Use

Block Parameter: DataFormat
Type: string | character vector
Values: 'raw data' | 'manually specified signals' | 'CANdb specified signals'
Default: 'raw data'

This option is available if you specify that your data is input through a CANdb file in the Data is input as list. Click Browse to find the CANdb file on your system. The message list specified in the CANdb file populates the Message section of the dialog box. The CANdb file also populates the Signals table for the selected message. File names that contain non-alphanumeric characters such as equal signs, ampersands, and so on are not valid CAN database file names. You can use periods in your database name. Before you use the CAN database files, rename them with non-alphanumeric characters.

Programmatic Use

Block Parameter: CANdbFile
Type: string | character vector

This option is available if you specify that your data is input through a CANdb file in the Data is input as field and you select a CANdb file in the CANdb file field. Select the message to display signal details in the Signals table.

Programmatic Use

Block Parameter: MsgList
Type: string | character vector

Specify a name for your CAN FD message. The default is CAN Msg. This option is available if you choose to input raw data or manually specify signals. This option is not available if you choose to use signals from a CANdb file.

Programmatic Use

Block Parameter: MsgName
Type: string | character vector

Specify the message protocol mode.

Programmatic Use

Block Parameter: ProtocolMode
Type: string | character vector
Values: 'CAN FD' | 'CAN'
Default: 'CAN FD'

Specify whether your CAN message identifier is a Standard or an Extended type. The default is Standard. A standard identifier is an 11-bit identifier and an extended identifier is a 29-bit identifier. This option is available if you choose to input raw data or manually specify signals. For CANdb specified signals, the Identifier type inherits the type from the database.

Programmatic Use

Block Parameter: MsgIDType
Type: string | character vector
Values: 'Standard (11-bit identifier)' | 'Extended (29-bit identifier)'
Default: 'Standard (11-bit identifier)'

Specify your message ID. This number must be a positive integer from 0 through 2047 for a standard identifier and from 0 through 536870911 for an extended identifier. You can also specify hexadecimal values by using the hex2dec function. This option is available if you choose to input raw data or manually specify signals.

Programmatic Use

Block Parameter: MsgIdentifier
Type: string | character vector
Values: '0' to '536870911'

Specify the length of your message. For CAN messages the value can be 0 to 8 bytes; for CAN FD the value can be 0 to 8, 12, 16, 20, 24, 32, 48, or 64 bytes. If you are using CANdb specified signals for your data input, the CANdb file defines the length of your message. This option is available if you choose to input raw data or manually specify signals.

Programmatic Use

Block Parameter: MsgLength
Type: string | character vector
Values: '0' to '8', '12', '16', '20', '24', '32', '48', '64'
Default: '8'

(Disabled for CAN FD protocol mode.) Specify the CAN message as a remote frame.

Programmatic Use

Block Parameter: Remote
Type: string | character vector
Values: 'off' | 'on'
Default: 'off'

(Disabled for CAN protocol mode.) Enable bit rate switch.

Programmatic Use

Block Parameter: BRSSwitch
Type: string | character vector
Values: 'off' | 'on'
Default: 'off'

Add a signal to the signal table.

Programmatic Use

None

Remove the selected signal from the signal table.

Programmatic Use

None

This table appears if you choose to specify signals manually or define signals by using a CANdb file.

If you are using a CANdb file, the data in the file populates this table and you cannot edit the fields. To edit signal information, switch to manually specified signals.

If you have selected to specify signals manually, create your signals in this table. Each signal that you create has these values:

Name

Specify a descriptive name for your signal. The Simulink block in your model displays this name. The default is Signal [row number].

Start bit

Specify the start bit of the data. The start bit is the least significant bit counted from the start of the message data. For CAN the start bit must be an integer from 0 through 63, for CAN FD 0 through 511, within the number of bits in the message. (Note that message length is specified in bytes.)

Length (bits)

Specify the number of bits the signal occupies in the message. The length must be an integer from 1 through 64. The sum of all the signal lengths in a message is limited to the number of bits in the message length; that is, all signals must cumulatively fit within the length of the message. (Note that message length is specified in bytes and signal length in bits.)

Byte order

Select either of these options:

  • LE: Where the byte order is in little-endian format (Intel®). In this format you count bits from the least significant bit, to the most significant bit. For example, if you pack one byte of data in little-endian format, with the start bit at 20, the data bit table resembles this figure.

    Little-Endian Byte Order Counted from the Least-Significant Bit to the Highest Address

  • BE: Where byte order is in big-endian format (Motorola®). In this format you count bits from the least-significant bit to the most-significant bit. For example, if you pack one byte of data in big-endian format, with the start bit at 20, the data bit table resembles this figure.

    Big-Endian Byte Order Counted from the Least Significant Bit to the Lowest Address

Data type

Specify how the signal interprets the data in the allocated bits. Choose from:

  • signed (default)

  • unsigned

  • single

  • double

    Note: If you have a double signal that does not align exactly to the message byte boundaries, to generate code with Embedded Coder® you must check Support long long under Device Details in the Hardware Implementation pane of the Configuration Parameters dialog.

Multiplex type

Specify how the block packs the signals into the message at each time step:

  • Standard: The signal is packed at each time step.

  • Multiplexor: The Multiplexor signal, or the mode signal is packed. You can specify only one Multiplexor signal per message.

  • Multiplexed: The signal is packed if the value of the Multiplexor signal (mode signal) at run time matches the configured Multiplex value of this signal.

For example, a message has four signals with these types and values.

Signal NameMultiplex TypeMultiplex Value
Signal-AStandardNot applicable
Signal-BMultiplexed1
Signal-CMultiplexed0
Signal-DMultiplexorNot applicable

In this example:

  • The block packs Signal-A (Standard signal) and Signal-D (Multiplexor signal) in every time step.

  • If the value of Signal-D is 1 at a particular time step, then the block packs Signal-B along with Signal-A and Signal-D in that time step.

  • If the value of Signal-D is 0 at a particular time step, then the block packs Signal-C along with Signal-A and Signal-D in that time step.

  • If the value of Signal-D is not 1 or 0, the block does not pack either of the Multiplexed signals in that time step.

Multiplex value

This option is available only if you have selected the Multiplex type to be Multiplexed. The value you provide here must match the Multiplexor signal value at run time for the block to pack the Multiplexed signal. The Multiplex value must be a positive integer or zero.

Factor

Specify the Factor value to apply to convert the physical value (signal value) to the raw value packed in the message. See the Data input as parameter conversion formula to understand how physical values are converted to raw values packed into a message.

Offset

Specify the Offset value to apply to convert the physical value (signal value) to the raw value packed in the message. See the Data input as parameter conversion formula to understand how physical values are converted to raw values packed into a message.

Min, Max

Define a range of signal values. The default settings are -Inf (negative infinity) and Inf, respectively. For CANdb specified signals, these settings are read from the CAN database. For manually specified signals, you can specify the minimum and maximum physical value of the signal. By default, these settings do not clip signal values that exceed them.

Programmatic Use

Block Parameter: SignalInfo
Type: string | character vector

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History

Introduced in R2018a