Power (3ph, Instantaneous)
Compute three-phase instantaneous active and reactive powers
Libraries:
Simscape /
Electrical /
Specialized Power Systems /
Sensors and Measurements
Description
The Power (3ph, Instantaneous) block computes the three-phase instantaneous active power P (in watts) and reactive power Q (in vars) associated with a periodic set of three-phase voltages and currents. These formulas are used to perform the calculations:
With these formulas, a current flowing into an RL circuit produces a positive P and a positive Q.
The computed instantaneous reactive power is accurate only for balanced and harmonic-free three-phase voltages and currents.
Examples
The power_ThreePhasePower
model compares the outputs of the
block with the Power (Positive-Sequence) block and the Power (dq0, Instantaneous)
block. It shows that the Power (3ph, Instantaneous) block gives accurate results
when the voltages and currents are balanced and harmonic free. When the voltage
supply becomes unbalanced, the P output exhibits a ripple, and an error appears on
the Q output.
The model sample time is parameterized by the Ts variable set to a default value
of 50e-6 s. Set Ts to 0 in the command window and change the Simulation
type parameter of the Powergui block to
Continuous
to simulate the model in continuous
mode.