Many model configuration parameters for code generation are specific to GRT, ERT, or ERT-based system target files.
Specify Generated Code Interfaces
Use interface model configuration parameters to control which libraries to use when generating code, whether to include support for an API in generated code, and other interface options.
To... | Select or Enter... |
---|---|
Specify the language standard that the code generator uses when generating code. | Select Selecting
For more information, see Language standard. The options for this parameter have dependencies. See Interface Dependencies. |
Specify an application-specific library that the code generator uses when generating code. | If you generate application-specific C or C++ code for math functions or
operations, select a value for Code replacement library.
Otherwise, specify For more information about code replacement libraries, see Choose a Code Replacement Library and Code replacement library. The options for this parameter have dependencies. See Interface Dependencies. |
Direct where the code generator places fixed-point and other utility code. | Select
|
Specify text to be added to the variable names used when logging data to MAT-files and to distinguish logging data from code generation and simulation applications. | Enter a prefix or suffix, such as |
Specify data exchange APIs to be included in generated code. | Select one or more C API options, the ASAP2 interface option, or the External mode option. When you select External mode, other options appear. The data exchange APIs are independent, and you can select combinations of these APIs. For example, you could choose C API and external mode. For more information on working with these interfaces, see Write External Code to Access Generated C API Code, Export ASAP2 File for Data Measurement and Calibration, and External Mode Simulations for Parameter Tuning, Signal Monitoring, and Code Execution Profiling. The options for this parameter have dependencies. See Interface Dependencies. |
a ANSI is a registered trademark of the American National Standards Institute, Inc. b ISO is a registered trademark of the International Organization for Standardization. |
Note
Before setting Language standard or Code replacement
library, verify that your compiler supports the library you want to use. If
you select a parameter value that your toolchain does not support, compiler errors can
occur. For example, if you select the language standard C99
(ISO)
and your compiler does not support the ISO C math extensions, compile-time errors could occur.
When the Embedded Coder® product is installed on your system, the Code Generation > Interface pane expands to include several additional options. For descriptions of Code Generation > Interface pane parameters, see Model Configuration Parameters: Code Generation Interface.
Several interface parameters have dependencies on settings of other parameters. The following table summarizes the dependencies.
Interface Dependencies
Parameter | Dependencies? | Dependency Details |
---|---|---|
Language standard | Yes | Available values depend on Language selection. |
Code replacement library | Yes | Available values depend on product licensing and other parameters. For more information, see Code replacement library. |
Shared code placement | No | |
Support: floating-point numbers (ERT system target files only) | No | |
Support: non-finite numbers | Yes (ERT) No (GRT) | For ERT system target files, enabled by Support floating-point numbers |
Support: complex numbers (ERT system target files only) | No | |
Support: absolute time (ERT system target files only) | No | |
Support: continuous time (ERT system target files only) | Yes | Requires that you disable Remove error status field in real-time model data structure. |
Support: non-inlined S-functions (ERT system target files only) | Yes | Requires that you enable Support floating-point numbers and Support non-finite numbers |
Terminate function required (ERT system target files only) | Yes | |
Code interface packaging | Yes | Available values depend on Language selection. |
Multi-instance code error diagnostic | Yes | Set Code interface packaging to Reusable
function or C++ class |
Pass root-level I/O as (ERT system target files only) | Yes | Set Code interface packaging to Reusable
function |
Use dynamic memory allocation for model initialization (ERT system target files only) | Yes | Set Code interface packaging to Reusable
function |
MAT-file logging | Yes | For GRT system target files, requires that you enable Support non-finite numbers; for ERT system target files, requires that you enable Support floating-point numbers, Support non-finite numbers, and Terminate function required |
MAT-file file variable name modifier | Yes | Enabled by MAT-file logging |
Remove error status field in real-time model data structure (ERT system target files only) | Yes | Requires that you disable Support: continuous time. |
Generate C API for: signals | No | |
Generate C API for: parameters | No | |
Generate C API for: states | No | |
Generate C API for: root-level I/O | No | |
ASAP2 interface | No | |
External mode | No | |
Transport layer | Yes | Enable External mode |
MEX-file arguments | Yes | Enable External mode |
Static memory allocation | Yes | Enable External mode |
Static memory buffer size | Yes | Enable Static memory allocation |
Configure Numeric Data Support
By default, ERT system target files support code generation for integer, floating-point, nonfinite, and complex numbers.
For more information, see Model Configuration Parameters: Code Generation Interface.
Configure Time Value Support
Certain blocks require the value of absolute time, elapsed time, or continuous time. Absolute time is the time from the start of program execution to the present time. Elapsed time is the time elapsed between two trigger events. Depending on the blocks used, your model could require adjustment of the configuration settings for supported time values.
To... | Select... |
---|---|
Generate code that creates and maintains integer counters for blocks that use absolute or elapsed time values (default). | Support absolute time. For further information on the allocation and operation of absolute and elapsed timers, see Timer Representation and Computation. If you do not select this parameter and the model includes a block that uses absolute or elapsed time values, the build process generates an error. |
Generate code for blocks that rely on continuous time. | Support continuous time. If you do not select this parameter and the model includes continuous-time blocks, the build process generates an error. |
For more information, see Model Configuration Parameters: Code Generation Interface.
Configure Noninlined S-Function Support
To generate code for noninlined S-Functions in a model, select Support noninlined S-functions. The generation of noninlined S-functions requires floating-point and nonfinite numbers. Thus, when you select Support non-inlined S-functions, the ERT system target file selects Support floating-point numbers and Support non-finite numbers.
When you select Support non-finite numbers and the model includes a C MEX S-function that does not have a corresponding TLC implementation (for inlining code generation), the build process generates an error.
Inlining S-functions is highly advantageous in production code generation, for example in implementing device drivers. To enforce the use of inlined S-functions for code generation, clear Support non-inlined S-functions.
When generating code for a model that contains noninlined S-functions with an ERT system target file, there can be a mismatch between the simulation and code generation results when either of the following is true:
Model configuration parameter
GenCodeOnly
is set tooff
.Model configuration parameter
ProdEqTarget
is set tooff
.
To avoid such a mismatch, set ProdEqTarget
to on
or set GenCodeOnly
to on
.
Configure Model Function Generation and Argument Passing
For ERT system target files, you can configure model for how functions are generated and how arguments are passed to the functions.
To... | Do... |
---|---|
Generate model function calls that are compatible with the main program module
of the pre-R2012a GRT system target file (grt_main.c or
.cpp ). | Select MAT-file logging. Clear Remove error status field in real-time model data structure. |
Reduce overhead and use more local variables by combining the output and update
functions in a single
function. | Select Single output/update function Errors or unexpected behavior can occur if a Model block is part of a cycle and the model configuration enables Single output/update function (the default). For more information about direct feed through, see Algebraic Loop Concepts. |
Generate a | Select Terminate function required (Embedded Coder). For more information, see the description of |
Generate reusable, reentrant code from a model or subsystem. | Select Generate reusable code. See Configure Code Reuse Support for details. |
Statically allocate model data structures and access them directly in the model code. | Clear Generate reusable code. The generated code is not reusable or reentrant. See Configure Generated C Function Interface for Model Entry-Point Functions for information on the calling interface generated for model functions in this case. |
Suppress the generation of an error status field in the real-time model data
structure, rtModel , for example, if you do not require to log or
monitor error messages. | Select Remove error status field in real-time model
data structure. Selecting this parameter can also cause the code generator to omit
the When generating code for multiple integrated models, set this parameter the same for all of the models. Otherwise, the integrated application could exhibit unexpected behavior. For example, if you select the option in one model but not in another, it is possible that the integrated application could not register the error status. Do not select this parameter if you select the MAT-file logging option. The two options are incompatible. |
Open the Configure C Step Function Interface dialog box and modify the
| In the Code Mapping Editor, on the Entry-Point
Functions tab, click in the Function Name column for the base-rate
step function. Click the three vertical dots that appear. Then click
Configure Prototype. Unless a function prototype was
previously configured, the dialog box opens showing a preview of the step function
interface without arguments ( |
For more information, see Model Configuration Parameters: Code Generation Interface.
Configure Code Reuse Support
For GRT, ERT, GRT-based, and ERT-based system target files, you can configure how a
model reuses code by setting the Code interface packaging
configuration parameter value to Reusable function
.
The Pass root-level I/O as configuration parameter provides
options that control how model inputs and outputs at the root level of the model are passed
to the
function. model
_step
To... | Select... |
---|---|
Pass each root-level model input and output argument to the
function individually
(the default) | Code interface packaging > Reusable function and Pass
root-level I/O as > Individual
arguments . |
Pack root-level input arguments and root-level output arguments into separate
structures that are then passed to the
function | Code interface packaging > Reusable function and Pass
root-level I/O as > Structure
reference . |
Pack root-level input arguments and root-level output arguments into the model data structure to support reentrant multi-instance code from a model for ERT system target file | Code interface packaging > Reusable function and Pass
root-level I/O as > Part of model data
structure . |
If using the Code interface packaging > Reusable function
selection, consider using
the Use dynamic memory allocation for model initialization option to
control whether an allocation function is generated. This option applies for ERT system
target files.
Sometimes, selecting Code interface packaging as Reusable function
can generate code that
compiles but is not reentrant. For example, if a signal, DWork
structure,
or parameter data has a storage class other than Auto
, global
data structures are generated. To handle such cases, use the Multi-instance code error diagnostic parameter to choose the severity levels for diagnostics.
Sometimes, the code generator is unable to generate valid and compilable code. For example, if the model contains one of the following, the generated code is invalid.
An S-function that is not code-reuse compliant
A subsystem triggered by a wide function-call trigger
In these cases, the build terminates after reporting the problem.
For more information, see Generate Reentrant Code from Top Models (Embedded Coder) and Model Configuration Parameters: Code Generation Interface.