Block priority violation
Diagnostic behavior when the software detects block priority specification error
Model Configuration Pane: Diagnostics
Description
This parameter specifies the diagnostic behavior when a block priority specification error occurs.
You can specify a priority order for executing block output methods during simulation. The software executes blocks with high priority order before blocks with lower priority order. The software uses the priority you specify only when the order is consistent with the block sorting algorithm. If you specify a priority order that is not consistent with the block sorting algorithm, a block priority specification error occurs.
Settings
warning
(default) | error
warning
The software issues a warning and ignores the specified block priorities.
error
The software issues an error and terminates the simulation.
Recommended Settings
Application | Setting |
---|---|
Debugging | No impact |
Traceability | No impact |
Efficiency | No impact |
Safety precaution | error |
Programmatic Use
Parameter: BlockPriorityViolationMsg |
Value: 'warning' | 'error' |
Default: 'warning' |
Version History
Introduced before R2006a