Check safety-related solver settings for simulation time
mathworks.hism.hisl_0040
Dependencies: Simulink® Check™
Usage: High-Integrity System Modeling
Guideline: hisl_0040: Configuration Parameters > Solver > Simulation time
Description
This check verifies that the model configuration uses optimal parameter settings pertaining to simulation time for generating code for a safety-related application.
Recommended Actions and Results
Review the violations that are flagged by the check and the recommended action for fixing the issue. After applying the changes, save the model and rerun the check analysis.
If you consider the flagged violation to either not be relevant or not feasible for your design, use the Justify button to provide rationale as to why the violation is either not relevant or not feasible for your design.
You can use the Fix button to allow the Model Advisor to fix all flagged violations. For this check, the Model Advisor configures model code generation settings that can impact safety.
Modeling Condition | Recommended Action |
---|---|
The start time for the simulation or generated code is set to a
value other than 0.0 . | Set model configuration parameter Start
time to 0.0 or set the
parameter StartTime to
'0.0' . |
The stop time for the simulation or generated code is set to a
negative value or a positive value greater than the value of Application lifespan (days). By default,
Application lifespan (days) is set to
auto for models configured to use a data code
interface. For models configured to use a service code interface,
the default is inf . If you do not change this
setting, a positive value for Stop time is valid. | Set model configuration parameter Stop time to a positive value that is less than the value of Application lifespan (days). |
Capabilities and Limitations
Does not require model compilation
Does not run on library models
Does not allow exclusions of blocks or charts
Version History
Introduced in R2020a
See Also
Topics
- Check Your Model Using the Model Advisor
- Address Model Check Results
- Save and View Model Advisor Check Reports
- Improve Simulation Performance Using Performance Advisor
- Upgrade Models Using Upgrade Advisor
- Use Model Advisor Configuration Editor to Customize Model Advisor
- Exclude Blocks from Model Advisor Check Analysis
- Justify Model Advisor Violations from Check Analysis
- Check Model Compliance Using Edit-Time Checking