Check Valve (G)
Check valve in a gas network
Libraries:
Simscape /
Fluids /
Gas /
Valves & Orifices /
Directional Control Valves
Description
The Check Valve (G) block represents an orifice with a unidirectional opening mechanism that prevents unwanted backflow. The opening mechanism responds to pressure, and opens the orifice when the pressure gradient falls from the inlet at port A to the outlet at port B. Check valves protect components upstream against pressure surges, temperature spikes, and chemical contamination stemming from points downstream.
The valve begins opening at the cracking pressure and continues opening until the end of the pressure regulation range. The cracking pressure is the initial resistance, due to friction or spring forces, that the valve must overcome to crack open. Below this threshold, the valve is closed and only leakage flow can pass. Past the end of the pressure regulation range, the valve is fully open and the flow at the maximum value is determined by the instantaneous pressure conditions.
The flow can be laminar or turbulent, and it can reach up to sonic speeds. The maximum velocity happens at the throat of the valve where the flow is narrowest and fastest. The flow chokes and the velocity saturates when a drop in downstream pressure can no longer increase the velocity. Choking occurs when the back-pressure ratio reaches the critical value characteristic of the valve. The block does not capture supersonic flow.
Control and Other Pressures
The pressure to which the valve responds is the control pressure. By default, the control pressure is the drop from inlet to outlet. This setting ensures that the valve closes if the direction of flow should reverse.
You can also specify the control pressure as the gauge pressure at the inlet. Use this setting if you know that the inlet will always be at a higher pressure than the outlet. For example, when the inlet connects to a pressure source, such as a pump.
You can select the control pressure by setting the Opening pressure
specification parameter to Pressure difference of port A
relative to port B
or Gauge pressure at port
A
.
When the Opening pressure specification parameter is
Pressure difference of port A relative to port B
:
The control pressure is:
where PA is the absolute pressure at port A and PB is the absolute pressure at port B.
The cracking pressure, PCrk, is the value of the Cracking pressure differential parameter.
The maximum pressure of the valve, PMax, where the valve is fully open, is the value of the Maximum opening pressure differential parameter.
When the Opening pressure specification parameter is
Gauge pressure at port A
:
The control pressure is
where PAtm is the atmospheric pressure specified in the Gas Properties (G) block of the model.
The cracking pressure, PCrk, is the value of the Cracking pressure (gauge) parameter.
The maximum pressure of the valve, PMax, where the valve is fully open, is the value of the Maximum opening pressure (gauge) parameter.
Fraction of Valve Opening
The degree to which the control pressure exceeds the cracking pressure determines how much the valve opens. The fraction of valve opening is
where:
PCtrl is the control pressure.
PCrk is the cracking pressure.
PMax is the maximum opening pressure.
The fraction is normalized so that it is 0
in the fully closed valve and
1
in the fully open valve. If the calculation returns a value
outside of these bounds, the block saturates the value to the nearest of the two
limits.
When the Smoothing factor parameter is nonzero, the block applies numerical smoothing to the normalized control pressure, . Enabling smoothing helps maintain numerical robustness in your simulation.
For more information, see Numerical Smoothing.
Valve Parameterizations
The block behavior depends on the Valve parametrization parameter:
Cv flow coefficient
— The flow coefficient Cv determines the block parameterization. The flow coefficient measures the ease with which a gas can flow when driven by a certain pressure differential.Kv flow coefficient
— The flow coefficient Kv, where , determines the block parameterization. The flow coefficient measures the ease with which a gas can flow when driven by a certain pressure differential.Sonic conductance
— The sonic conductance of the resistive element at steady state determines the block parameterization. The sonic conductance measures the ease with which a gas can flow when choked, which is a condition in which the flow velocity is at the local speed of sound. Choking occurs when the ratio between downstream and upstream pressures reaches a critical value known as the critical pressure ratio.Orifice area
— The size of the flow restriction determines the block parametrization.
The block scales the specified flow capacity by the fraction of valve opening. As the
fraction of valve opening rises from 0
to 1
,
the measure of flow capacity scales from its specified minimum to its specified
maximum.
Momentum Balance
The block equations depend on the Orifice parametrization parameter.
When you set Orifice parametrization to Cv
flow coefficient parameterization
, the mass flow rate, , is
where:
Cv is the flow coefficient.
N6 is a constant equal to 27.3 for mass flow rate in kg/hr, pressure in bar, and density in kg/m3.
Y is the expansion factor.
pin is the inlet pressure.
pout is the outlet pressure.
ρin is the inlet density.
The expansion factor is
where:
Fγ is the ratio of the isentropic exponent to 1.4.
xT is the value of the xT pressure differential ratio factor at choked flow parameter.
The block smoothly transitions to a linearized form of the equation when the pressure ratio, , rises above the value of the Laminar flow pressure ratio parameter, Blam,
where:
When the pressure ratio, , falls below , the orifice becomes choked and the block switches to the equation
When you set Orifice parametrization to Kv flow
coefficient parameterization
, the block uses these same
equations, but replaces Cv with
Kv by using the relation . For more information on the mass flow equations when the
Orifice parametrization parameter is Kv
flow coefficient parameterization
or Cv flow
coefficient parameterization
, see [2][3].
When you set Orifice parametrization to
Sonic conductance parameterization
, the mass flow
rate, , is
where:
C is the sonic conductance.
Bcrit is the critical pressure ratio.
m is the value of the Subsonic index parameter.
Tref is the value of the ISO reference temperature parameter.
ρref is the value of the ISO reference density parameter.
Tin is the inlet temperature.
The block smoothly transitions to a linearized form of the equation when the pressure ratio, , rises above the value of the Laminar flow pressure ratio parameter Blam,
When the pressure ratio, , falls below the critical pressure ratio, Bcrit, the orifice becomes choked and the block switches to the equation
For more information on the mass flow equations when the Orifice
parametrization parameter is Sonic conductance
parameterization
, see [1].
When you set Orifice parametrization to
Orifice area parameterization
, the mass flow
rate, , is
where:
Sr is the orifice or valve area.
S is the value of the Cross-sectional area at ports A and B parameter.
Cd is the value of the Discharge coefficient parameter.
γ is the isentropic exponent.
The block smoothly transitions to a linearized form of the equation when the pressure ratio, , rises above the value of the Laminar flow pressure ratio parameter, Blam,
When the pressure ratio, , falls below , the orifice becomes choked and the block switches to the equation
For more information on the mass flow equations when the Orifice
parametrization parameter is Orifice area
parameterization
, see [4].
Mass Balance
The block assumes the volume and mass of fluid inside the valve is very small and ignores these values. As a result, no amount of fluid can accumulate in the valve. By the principle of conservation of mass, the mass flow rate into the valve through one port equals that out of the valve through the other port
where is defined as the mass flow rate into the valve through the port indicated by the A or B subscript.
Energy Balance
The resistive element of the block is an adiabatic component. No heat exchange can occur between the fluid and the wall that surrounds it. No work is done on or by the fluid as it traverses from inlet to outlet. Energy can flow only by advection, through ports A and B. By the principle of conservation of energy, the sum of the port energy flows is always equal to zero
where ϕ is the energy flow rate into the valve through ports A or B.
Assumptions and Limitations
The
Sonic conductance
setting of the Valve parameterization parameter is for pneumatic applications. If you use this setting for gases other than air, you may need to scale the sonic conductance by the square root of the specific gravity.The equation for the
Orifice area
parameterization is less accurate for gases that are far from ideal.This block does not model supersonic flow.
Examples
Ports
Conserving
Parameters
References
[1] ISO 6358-3. "Pneumatic fluid power – Determination of flow-rate characteristics of components using compressible fluids – Part 3: Method for calculating steady-state flow rate characteristics of systems". 2014.
[2] IEC 60534-2-3. "Industrial-process control valves – Part 2-3: Flow capacity – Test procedures". 2015.
[3] ANSI/ISA-75.01.01. "Industrial-Process Control Valves – Part 2-1: Flow capacity – Sizing equations for fluid flow underinstalled conditions". 2012.
[4] P. Beater. Pneumatic Drives. Springer-Verlag Berlin Heidelberg. 2007.