Get exact value from Scope cursor in Simulink

31 views (last 30 days)
I am using the vertical Cursors in a Scope window to find the signal value. However, the value only displays three significant numbers behind the comma. In my example, it shows 2.202e+07:
Can I get the signal value with more significant numbers somehow? The signal in this case is actually a uint32 signal where each bit represents something, so I need to get the exact uint32 value.

Accepted Answer

Sahil Jain
Sahil Jain on 2 Sep 2021
Hi Jonas. As of R2021a, it is not possible to increase the number of digits shown in the Scope block window. As a workaround, you can export the signals to the workspace (see "to workspace" block) and use the "format" function to set the format style to 'long' and print the values to the console.

More Answers (0)

Products


Release

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!