Floating scope will not display data (wired scope ok)
4 views (last 30 days)
Show older comments
How do I use a floating scope? Wired scope to the same signal works fine. With the floating scope, I select the signal through 'Signal Selection' on the scope, run the simulation, see data in the wired scope, see not data in the floating scope and autoscale is 'greyed' out as if no data is there.
How do I get this to work?
0 Comments
Answers (3)
Paul Costa
on 8 Jan 2015
Have you cleared the "Signal storage reuse" check box from the Configuration Parameters dialog? Here's some info from the documentation:
Before using a Floating Scope in a simulation, clear the Signal storage reuse check box in the Optimization > Signals and Parameters pane of the Configuration Parameters dialog box. For more information, see Optimization Pane: Signals and Parameters.
0 Comments
Paul Moore
on 8 Jan 2015
1 Comment
Paul Costa
on 9 Jan 2015
Sorry for the trouble. I suggest you send your example model and relevant information (MATLAB version, OS, etc) to support@mathworks.com. They should be able to help you sort this out.
Nathan Zimmerman
on 9 Feb 2017
Having a similar issue. Signals from a model reference that are test-pointed won't display. You check them, then you run the simulation and they uncheck themselves. No error/warning messages appear as to why that might be.
0 Comments
See Also
Categories
Find more on View Data During Simulation in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!