Extremely small flow rates?
Show older comments

I am building a system where a hydraulic pump/motor uses a angular/torque source to draw fluid from a reservoir into a gas charged accumulator, when the gas charged accumulator is filled up and pressurised, the fluid is released and powers the pump/motor, the fluid travels to the reservoir and the cycle repeats. With some help from the MATLAB community, I have a working system, however the flow rates measured by the sensor are extremely low to the magnitude of 10^-7, and I don't know why that is. Also the cycle does not repeat. Capacity for both accumulator and reservoir are 40L and pre-load pressure 5e-3. Changing the angular velocity doesn't effect the results. Ode23 is used.
Accepted Answer
More Answers (0)
Categories
Find more on Upgrading Hydraulic Models to Use Isothermal Liquid Blocks in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!