hello, guys,when i run the simulation, i found the scope not display the line with the time change, it keep stop at the begining, why, how to resolve

Accepted Answer

Satwik Samayamantry
Satwik Samayamantry on 8 Jul 2023
Hello, you are connecting a constant block to the scope which is expected to work as shown only. But if you want to show the signal changing with time, you should connect to a time changing signal.

More Answers (1)

Paul
Paul on 8 Jul 2023
Hi wenchao zhang,
The Constant block, by default, has a constant sample time. For the model shown, constant sample time means that the output of the block is computed only once at the start of the simulation, as indicated by the scope. If you want to see the constant line in the scope, one way is to change the Constant block's sample time parameter to 0, i.e., continuous sample time.
  1 Comment
wenchao zhang
wenchao zhang on 8 Jul 2023
thank you,Paul, yes,i will try it later, i think this is the root cause

Sign in to comment.