Hi,
There is a big mistake in the inductance equation of the Five-Phase PMSM block (please see the link given below). There is no way to adjacent phase mutuals equal to non-adjacent (remote) mutuals as given below. Lab can not equal Lce or Lea can not equal Lbd.
Lab=Lba=Lce=Lec=−Ms+Lmcos(2(θe−2π/5))
Lea=Lae=Lbd=Ldb=−Ms+Lmcos(2(θe+2π/5))
Please prove me wrong. Now, I think maybe there are also mistakes in other equations too! Are there any correct equations or explanations?