My aim is to integrate a Simulink protected model which runs on variable step solver with our vehicle plant model which runs on Fixed step solver ode1 with a time step of 1ms. I would like to know if it is possible to do the same. Any ideas would be appreciated.
0 Comments
Accepted Answer
Paul
on 28 Apr 2024
R2022a introduced the concept of a "Local Solver" when using referenced models, which might be what you're looking for. This blog post, and the comments, along with the current, relevant doc pages might be of interest.
0 Comments
More Answers (1)
Torsten
on 28 Apr 2024
Moved: Torsten
on 28 Apr 2024
Given: Results for both models at time t.
- Call the variable step solver for a time period of 1 ms (maybe using the inputs of the fixed step solver at time t).
- Call the fixed step solver for a time period of 1 ms (maybe using the inputs of the variable step solver at time t).
- Set t = t + 1ms.
- Goto 1.
1 Comment
Paul
on 28 Apr 2024
Edited: Paul
on 29 Apr 2024
My initial reaction to this answer was "that's not how Simulink works, at least not easily." But, with R2024a Simulink implemented a new feature called Simulation Objects that may make this approach workable, especially if the protected model and the vehicle plant model only interact with each other at well-defined times. I haven't yet tried Simulation Objects. See this blog post and the doc page(s) linked from there for more information.