error in Simulink simulation time
1 view (last 30 days)
Show older comments
I simulate a model in Simulink with a discrete solver, the result of simulation is limited to a reduced interval e6 à10e6 even if I set the simulation time from 0 to 10e6, what is the parameter to change to remedy
0 Comments
Answers (2)
Sebastian Castro
on 13 May 2015
1 - Block-dependent settings:
Check if any of your blocks have an explicit sample time that is too small, by going to Display --> Sample Time --> All and looking at the colors/labels.
2 - Global model settings:
Go to your Configuration Parameters (Ctrl+E). In the Solver pane, see if you have set your Max step-size (or if fixed-step, your regular step-size) to this small number.
- Sebastian
0 Comments
studentU
on 13 May 2015
5 Comments
Sebastian Castro
on 13 May 2015
If it's the Y-axis, you can just right-click the scope axes and you will get 2 important options:
- Axes properties: Lets you manually enter values for Y-min and Y-max, depending on how you want your plot to look.
- Autoscale: It will scale the Y-axis automatically to fit all the data
There is also an "Autoscale" button on the scope toolbar. It should look like a square with 4 arrows pointing out at the corners.
See Also
Categories
Find more on Event Functions in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!