problem while tuning PID controller
Show older comments
I try to tune a PID-Controller in Matlab2010b if i use a discrete one i get the error Message "The second input argument of the "d2d" command must be a positive scalar." if i use a continuous one i get "Input to SVD must not contain NaN or Inf." what i have to pay attention that this block works fine? My system can became NaN due to a Sqrt-expression....
Accepted Answer
More Answers (4)
Arkadiy Turevskiy
on 12 Dec 2011
0 votes
Can you provide the plant model?
Martin1986
on 13 Dec 2011
0 votes
Yoni
on 19 Jan 2012
0 votes
Hi Martin,
I've had the same problem.
It seems the discrete PID option does not handle a sampling time of "-1" (should have inherited the sampling time it that case)
So the workaround for your problem is to enter your own explicit expression for the sampling time. do not leave it on "-1".
This should eliminate the "The second input argument of the "d2d" command must be a positive scalar."
Cheers, Yoni
1 Comment
Nail
on 14 May 2018
Also, simulation time must not be set to "inf".