fdatool to fpga
7 views (last 30 days)
Show older comments
I used fdatool to create VHDL of a lowpass fir filter with Fpass 1KHz and and Fstop 2KHz with sampling freq 20kHz.
I have a 12 bit ADC/DAC with a range from about -1.5V to 1.5V or -2048 to 2048 in signed binary. When I quantize the filter should I make the fraction length 0 so I get the +-2048 range or 10 so I get a range of +- 4V?
I am using a function generator for the input to the ADC.
0 Comments
Accepted Answer
Abhishek Gupte
on 11 Jan 2012
When you select the 'Set quantization parameters' tool in FDATOOL, in the 'Coefficients' tab, I would recommend checking the 'Best precision fractional length' checkbox. In the 'Input/Output' tab, you can set the 'Input range' to 1.5 V. I think that letting FDATOOL compute the best fractional length is the right way to go.
More Answers (0)
See Also
Categories
Find more on Filter Analysis in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!