Simulink shows only the last 2 second of simulation time
    6 views (last 30 days)
  
       Show older comments
    
Hello,
My Simulink model of an induction machine run about 2 second even if the simulation time is 20 sec. any idea on that?
The model is include of 3-phase to d-q model and then transforming to rotor reference model. the last step is deriving currents and applying the electrical torque and the mechanical torque has not been implemented yet. sot machine is working in no-load condition.
Regards,
0 Comments
Accepted Answer
  Andreas Goser
    
 on 9 Feb 2012
        Please verify the scope setting: Parameters - Data History - Limit Data Point to last.
The default is it is checked and limited to 5000 points.
More Answers (0)
See Also
Categories
				Find more on Building and Simulating Electronic, Mechatronic, and Electrical Power System Networks in Help Center and File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!