Using set_param with Configuration Set Reference

9 views (last 30 days)
I have a medium sized Simulink project using Configuration Reference to tie all the submodels (Model Reference) to one Configuration set. Is there a way to change the configuration parameters from the command line using set_param? I get the error:
A configuration set reference does not allow writing to parameters in the source configuration set

Answers (1)

Tiago Grossinho
Tiago Grossinho on 18 Jul 2017
Hello,
You probably have your question answered 1 year later, but for reference, I found my answer in the following page:
Chapter " §Change Values in a Referenced Configuration Set". Indeed, if you " Get" the config set which corresponds to the active one in your model, the set_param operation will immediately set the value in the model. My example:
>> get_param('model_name','RTWCAPISignals')
ans =
on
>> cref=getConfigSet('model_name','Reference');
>> cset = cref.getRefConfigSet;
>> set_param(cset,'RTWCAPISignals','off');
>> get_param('model_name','RTWCAPISignals')
ans =
off
Hoping it may help someone in the future, or even myself when I forget it one day! :)
  2 Comments
Gergely Takacs
Gergely Takacs on 9 May 2022
Thank you for the tip. Not entirely user friendly to figure this out:)