Equilibrium point simpower system multimachine model.

1 view (last 30 days)
If I run a load flow, I suppose that the states relates to a simplified synchronous machine remain constant until a disturb occur, but when I run a Phasor simulation, the Rotor angle and the Rotor speed present a little variation. So, Can this little variation be given by the solution calculated for the numeric method?

Answers (1)

Joel Van Sickel
Joel Van Sickel on 17 Sep 2020
Hello Luis,
in phasor simulation, everything is held to a fixed frequency. If you want to explore the dynamics of rotor speed changing, I would recommend using a continuous simulaiton instead. This still works with initializaiton through load flow. However, the fact that rotor angle isn't changing is problematic unless your rotor speed is zero. I wonder if something else is wrong.
Regards,
Joel

Categories

Find more on Simscape Electrical in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!