Clear Filters
Clear Filters

Synchronous Machine parameters rules.

2 views (last 30 days)
luis ramon merchan villalba
Edited: kia Na on 16 Apr 2018
Hi, I had a problem in the assignment of the parameters in the "Synchronous Machine pu Standard" model. The theory indicates that this rule must be given in the parameters.
X_d >= X_q > X_q' >= X_d' > X_q''>= X_d''
T_{do}' > T_{do}''
T_{qo}' > T_{qo}''
but even under this condition, Simulink tells me that the parameters are not consistent. What are the rules for assigning these parameters?

Answers (1)

kia Na
kia Na on 16 Apr 2018
Edited: kia Na on 16 Apr 2018
I have the same problem. Did you find out the solution?