I found something else. There is an old blog post about it (here) that describes the idea. In the Model Explorer window (where you define data and its Scope type), when you click on a data, on your right hand side you can set certain parameters of the data.
Click on the Logging tab, and tick the Log signal data box.
This is a screenshot from my example.
After that, once you run the simulation, click on the Simulation Data Inspector button (beside the Simulation stop time box, top side of the Simulink window) and you can see the logged data there.
In the screenshot above, it's the one in the red circle.
I think it would turn yellowish once you run the simulation and you have a logged data.
I think this is how you can test the model without physically altering the blocks, which is what you are looking for.