When I open a model's test harness, I receive the following error:
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?

Accepted Answer

Fangjun Jiang
Fangjun Jiang on 9 Apr 2020
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
  3 Comments
Fangjun Jiang
Fangjun Jiang on 20 Apr 2020
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
Monika Jaskolka
Monika Jaskolka on 20 Apr 2020
Edited: Monika Jaskolka on 20 Apr 2020
Thank you. You're right. I can enable the parameter by modifying the custom .tlc file like this:
slConfigUISetEnabled(hDlg, hSrc, 'ModelReferenceVersionMismatchMessage', 'true');