problem with PID tuning / Estimating frequency response of simulink model
Show older comments
i am having problem in designing PID (4 PI controller) for simulation model (vector control of induction motor). with PID tuner, it say linearization is failed.then i tried for Estimated Frequency Response by.
>> mdl = 'vcim'; %% simulink model vcim.mdl
>> open_system(mdl);
>> sim(mdl);
>> io = getlinio(mdl)
1x1 vector of Linearization IOs:
--------------------------
1. Linearization input-output located at the following signal:
- Block: vcim_d/Bus Selector1
- Port: 4
>> linsys = linearize(mdl,io)
d =
<Rotor speed
<Rotor speed 1
Static gain.
>> in = frest.Sinestream('Frequency',logspace(-1,1,50),'Amplitude',1e-3);
>> sys= frestimate(mdl,io,in);
---
after writing 'frestimate(mdl,io,in)' it take *too long time* to evaluate , even i could not evaluate above command after waiting for *half an hour* . it is cumbersome to use this method on my laptop config(Processor: Intel(R) Pentium(R) CPU B960 @ 2.20GHz (2 CPUs), ~2.2GHz).
even my simulation of model takes long time with
variable step solver(max step size 1e-6)
solver ode23tb (stiff/TR-BDF2)
at simulation time .1 sec
Accepted Answer
More Answers (1)
Arkadiy Turevskiy
on 7 Mar 2014
0 votes
We just shipped new functionality in 14a to specifically address this scenario. Take a look here: PID Controller Tuning for a Model with Discontinuities .
Categories
Find more on Troubleshooting in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!