Block IO Outport Code Generation

I have a s function with output port. The output of the port is stored as Block Signals (auto storage) and its defined by function \rtw\c\tlc\mw\commonhdr_blkiolib.tlc
How to change the output port character not to generate this temporary variable?

3 Comments

Did you want the output to reuse the input buffer?
I could change the behavior by adding below functions. Not the best solution but improved memory by lot
ssSetOutputPortReusable(S, 0, 1)
ssSetInputPortOverWritable(S, 0, 1);
Yes, that is what I was going to suggest. Could you explain what your ideal solution would be?

Sign in to comment.