Peak and Threshold SNR given an Average False Alarm Rate
Given an average False Alarm Rate (FAR), a pulse duration (tau), and a desired probability of detection (Pd), this routine will determine the Peak Signal to Noise Ratio (SNR) and Threshold SNR required to achieve the desired Pd in white noise. The output has been validated against the RCA Electro-Optics Handbook published in 1975.
Code is Vectorized for speed therefore all inputs can be multi-dimensional as long as they can be multiplied together using the [.] MATLAB notation.
Cite As
Darin Koblick (2024). Peak and Threshold SNR given an Average False Alarm Rate (https://www.mathworks.com/matlabcentral/fileexchange/71463-peak-and-threshold-snr-given-an-average-false-alarm-rate), MATLAB Central File Exchange. Retrieved .