Why does the DB function not return the proper power ratio in Signal Processing Toolbox?

I expect DB to always be power ratio and not amplitude ratio. Hence, dB should equal 10*log10 (value) and not 20*log10(value) for amplitude to power conversion.

 Accepted Answer

This bug has been fixed in Release 2007a (R2007a). For previous product releases, read below for any possible workarounds:
Generally for engineers of communications and electronics background, "dB" unit represents a ratio, for example, between input and output. On the other hand "dBm" unit represents a magnitude of power. However, in this case "dB" is used as a magnitude of power.
You can use the following syntax of the DB function as a workaround. If X is the value in question, use:
db(X,'power')
To get the 10*log10(X) instead of the 20*log10(X).

More Answers (0)

Categories

Find more on MATLAB in Help Center and File Exchange

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!