Co-simulation with HDL Verifier and ModelSim Altera Edition 10.1d
13 views (last 30 days)
Show older comments
I am attempting to complete the HDL Verifier Tutorial "Verify Raised Cosine Filter Design With Generated Simulink Test Bench. I reach the step "Select HDL Modules for Cosimulation (Simulink). I follow tutortial directions and then press next. The wizard then attempts to launch HDL Simulator but times out/
In the MATLAB Command Window I get the following warnings: Warning: ModelSim Altera edition is not supported by HDL Verifier
In log file I get: Error: (vsim-FLI-3155) The FLI is not enabled in this version of ModelSim.
When I try from Simulink I get: Error reported by S-function 'shdlcosim' in 'viterbi_modelsim/viterbi_hdl/S-Function': Failed to connect to server. Make sure the loaded HDL simulator library is using shared memory
I have found others that appear to have a similar issue, and the answer has been simply that Altera Modelsim is not supported by HDL Verifier.
My question is if there is any work around.
Thanks
0 Comments
Accepted Answer
Tao Jia
on 7 May 2014
Unfortunately, there is no workaround. The best way is to use one of the ModelSim versions supported by HDL Verifier, e.g., ModelSim PE.
More Answers (0)
See Also
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!