Clear Filters
Clear Filters

Build errors with Simulink CAN Transmit block on Raspberry Pi with CAN_MESSAGE as input

4 views (last 30 days)
Hello,
I have a problem with the CAN-Transmit block from the Raspberry Pi Simulink hardware support package. If I put a CAN Pack block in front of the Transmit block and set the input datatype to CAN_MSG for the Transmit block, I get the following error message during the build process:
The data type of input port 1 is 'CAN_MESSAGE'. MATLAB System block 'CAN Transmit' only supports built-in, binary point scaling [Slope=1.0, Bias=0.0], Simulink enumeration, and bus data types.
Tested with Simulink 2021b and 2022a.
Does anyone have the same problem or a solution for me?

Answers (1)

Vikky Patil
Vikky Patil on 10 Nov 2022
Try enabling "Output as bus" in CAN Pack block and then rebuild the model

Products


Release

R2022a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!