Error using () Data type mismatch at signal 'c_out'.This port expects a Logic data type of size 1
5 views (last 30 days)
Show older comments
This is my full adder code
module fulladder ( input [3:0] a,
input [3:0] b,
input c_in,
output c_out,
output [3:0] sum);
assign {c_out, sum} = a + b + c_in;
endmodule
Im trying to run cosimWizard from matlab.
In output port details pane, i selected Double data type for c_out, and fixedpoint signed datatype for sum.
but im getting the below error
Error using ()
Data type mismatch at signal 'c_out'.This
port expects a Logic data type of size 1
what should i assign output datatypes for c_out and sum?
0 Comments
Answers (1)
Marc Erickson
on 14 Nov 2022
The module port declarations are (implicitly) declaring c_out and sum as net types of wire and data type of logic (1 bit and 4 bits respectively). The cosimulation interface will expect Simulink or MATLAB data types that match the bit widths in the Verilog.
I do not understand what the module implementation is trying to do, but you should reexamine that.
To use 'double' in MATLAB/Simulink: in Verilog, use a 64bit logic type and the $bitstoreal / $realtobits system functions.