Baseline Criteria: How to read discrete data from excel rather than continuous data.

1 view (last 30 days)
I am using baseline criteria to verify the model.I am stuck with one issue which is causing test case failure.
When i am trying to data output from excel,it's reading continous value like when value change from 1 to 3 wiith time terveral of 1sec then it should change without any slope.
Inshort there is any way to read daat at disctre point(time sampling = 1sec)
Below image have output data and graph.
I wanted to read data 1 to 3 as a direct jump rather than any slopy transition.

Answers (1)

Walter Roberson
Walter Roberson on 19 May 2022
https://www.mathworks.com/help/simulink/slref/fromspreadsheet.html
configure Interpolation to "zero order hold"

Products


Release

R2017b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!