Simulink.B​lockDiagra​m.arrangeS​ystem does not work inside library

Hello,
I'm using the command:
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true');
to sort and rearrange the blocks inside a masked subsystem. This worked fine until I converted this subsystem into a library block.
Now this command does nothing and the internal structure remains cluttered and unreadabel. Because this blocks heavily modifies itself, I can't establish a pleasant alignment beforehand.
Is there any way to get this working?

4 Comments

No, it is locked.
Further testing showed, that the command seems to work only once (after getting a fresh copy of the library-block into the model) and then does nothing.
Sorry, to be acurate, for the library block, I shall refer it as "is the LinkStatus inactive".

Sign in to comment.

Answers (1)

I've tried it. You need to disable the library link first.
set_param(gcb,'LinkStatus','inactive')
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true')

2 Comments

Although that's working, I don't want to keep the 'LinkStatus' in the 'inactive' state.
(Restoring it isn't possible because the local instance has different blocks inside, which will get deleted.)
Since the command only works the first time after placing the library-block (as mentioned in my comment above), my workaround is the following:
Everytime I need to change / update a setting inside the mask of the librry-block, I place a new instance and delete the old one.