Embedded Coder - Sequence of commands
Show older comments
We use the Simulink Embedded Coder to generate C-Code for our DSP-System. For the input-signals the Real-Time Interrupt Service Routine needs to read out several signals from a Bus, which is made with self-programmed interface-blocks in the Simulink model. During code generation, the blocks, which finally produce few lines of C-code, are placed in the file model_step.c, which is called from the ert_main.c The order of appearance of the read-out commands depends on the model, i.e. at what time the signals are needed during execution. For example, a value from an analog-digital-converter might be read out right at the beginning of the ISR. This can cause a problem, since the analog-digital-converter needs a short time after the interrupt to update its values. So, is there any possibility to influence the placement of these commands within the ISR? Thank you for your help!
Accepted Answer
More Answers (0)
Categories
Find more on Timers and Scheduling in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!