PLC Coder does not support the usage of machine parented data. How can I solve it?
2 views (last 30 days)
Show older comments
I am currently working on Stateflow (Simulink) to generate a PLC Code compatible with Rockwell.
I am currently facing incompatibility issue: PLC Coder does not support the usage of machine parented data objects. How can I solve it without deleting such data?
Thanks
0 Comments
Accepted Answer
Shivang
on 4 Sep 2023
Hi Alice,
I understand you're running into an issue regarding the usage of machine-parented data objects in Stateflow.
Note that starting in R2023a, Stateflow charts no longer support machine-parented data. You will need to convert machine-parented data to chart-parented data store memory.
You can run Upgrade Advisor to fix this issue. Upgrade Advisor will automatically check the model for instances of machine-parented data. You will then be presented with an option to "Upgrade model", which will create chart-parented data in the charts that use machine-parented data.
Refer to the documentation for more details: https://www.mathworks.com/help/simulink/slref/simulink-checks_bq6d4aa-1.html#mw_94a64beb-dfcf-44c3-af52-82eaa725bc06
Hope this helps.
-Shivang
0 Comments
More Answers (0)
See Also
Categories
Find more on Simulink PLC Coder in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!