Hi,
In Simulink AUTOSAR Blockset, I have a list of SharedParameters. I have a few of these parameters that I would like to auto-tune. Meaning that I have a Stateflow routine that calibrate the values. Once the routine is done, I would like to write back the results in the external interface (to let the RTE/BSW saving it in non-volatile memory).
Does someone knows how to do that?
Regards, Nicolas
0 Comments
Accepted Answer
praguna manvi
on 2 Dec 2024
Edited: praguna manvi
on 2 Dec 2024
As I see, you are looking to calibrate AUTOSAR after using a Stateflow routine. You can configure "per-instance memory (PIM)" for AUTOSAR applications for this use case. In the AUTOSAR run-time environment, calibration tools can access "arTypedPerInstanceMemory" blocks for calibration and measurement. Refer to the link below for more information:
To preserve state information at startup and shutdown, the documentation above uses "NVRAM" block state data. Additionally, here is a useful discussion thread on using data in "Stateflow" for "PIM":
Hope this helps!