whenever i put 5 servos blocks in simulink, it keeps crashing and this error comes out:
Error occurred while executing External Mode MEX-file 'ext_comm':
ExtTargetPktPending() call failed while checking for target pkt
. i'm using arduino mega 2560
5 flex sensors
5 servo motors
windows 10 64-bit.
matlab 2017b
but if only one servo block used then it will not crash.
i see many people have this problem. and it still does not solve.
we pay for matlab and all staffs for education and work.
please help us or me solve it
if it is not important, we won't ask.
regards
Help please
0 Comments
Accepted Answer
More Answers (3)
Scott Huang
on 11 Jan 2019
Edited: Scott Huang
on 11 Jan 2019
Hi
you can try this: set your baud rate to 921600. Probably your baud rate is below this value. This solved my same problem.
codertarget.arduinobase.registry.setBaudRate('mdl',921600)
mdl = your model name
3 Comments
Scott Huang
on 11 Jan 2019
you also need to update the same setting some where in the "code"
I couldn't find what is the maximum allowed baud rate in the serial port setting, but I think this is the limit of your system.
another case reported that 3rd party arduino board may not support high baud rate because of the chip, maybe this is the root cause for your case.