using the command "port_label('input', 1, 'a') " , others port label disappeared!

4 views (last 30 days)
I mask the mode with 3 input , 1 output port,
I want to change one port label dynamically with differnt input, when I use the command "port_label('input', 1, 'a') " in Icon drawing command,
why other port labels disappear?
how can I fix the problem?

Answers (1)

Riya
Riya on 25 Feb 2025
Hi,
I understand that you want to change one port label dynamically while keeping the other labels unchanged. The issue is, when you use “port_label” inside the “Icon Drawing Commands”, it overrides all existing port labels rather than modifying them. So, on specifying the “port_label” command for just one port, Simulink will not display the other port labels.
To fix this, you can specify all port labels in the “Icon Drawing Commands” in the mask editor.
For example, if you have 3 input ports and 1 output port and you want to keep the first input port’s label dynamic, you can use the following code inside “Icon Drawing Commands”:
% Define the dynamic label for the first input
label1 = get_param(gcb, 'port1_label');
% Set labels for all ports explicitly
port_label('input', 1, label1);
port_label('input', 2, 'b');
port_label('input', 3, 'c');
port_label('output', 1, 'y');
This will ensure that when you change the first port's label dynamically, the other port labels remain visible.
Here is a sample output of the above code for your reference:
Thanks!

Categories

Find more on Author Block Masks in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!