I'm facing a problem of incompatibility between the blocks from Simulink Simscape and Simscape Specialized Power Systems blocks. I need a simple switch that work with the Asynchronous Machine block from Specialized Power Systems. It would also be nice to have a Phase Permute block compatible with Specialized Power Systems. I have to use this Asynchronous Machine block instead of the other Induction Machine blocks available because I need information about the current in the rotor's resistor and this is the only model I found that provides this information. None of the switch blocks I found are compatible with this library (Specialized Power Systems). Is there any? How can I solve this? Thank you