Fuel cell stack model equations. why 60000 on stack utilisation equation?
Show older comments
why did you use 60000 on the fuel cell stack model on utilsation equations?
1 Comment
Walter Roberson
on 24 Feb 2013
Context would help.
Answers (1)
Joel Van Sickel
on 11 Dec 2020
0 votes
Hello Leo, I assume this is in reference to the equations under the hood: 60000*FC.Nc*u(2)*FC.R*u(5)/(FC.z*FC.F*u(4)*FC.Pstd*u(3)*u(1))
From the docuentation on this block:
The 60000 constant comes from the conversion from the liter/min flow rate used in the model to m3/s (1 liter/min = 1/60000 m3/s).
Categories
Find more on Simscape Electrical in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!