Statistics
RANK
4,764
of 302,057
REPUTATION
10
CONTRIBUTIONS
0 Questions
8 Answers
ANSWER ACCEPTANCE
0.00%
VOTES RECEIVED
1
RANK
6,813 of 21,525
REPUTATION
161
AVERAGE RATING
5.00
CONTRIBUTIONS
6 Files
DOWNLOADS
34
ALL TIME DOWNLOADS
2848
RANK
of 178,541
CONTRIBUTIONS
0 Problems
0 Solutions
SCORE
0
NUMBER OF BADGES
0
CONTRIBUTIONS
0 Posts
CONTRIBUTIONS
0 Public Channels
AVERAGE RATING
CONTRIBUTIONS
0 Discussions
AVERAGE NO. OF LIKES
Feeds
Submitted
Motor Control with PFC using Microchip Kit
Sensorless Field‑Oriented Control of PMSM with Power Factor Correction on Microchip MCHV‑230VAC‑1.5kW Development Board
13 days ago | 2 downloads |
How does this block diagram convert input current to per unit value?
This implementation assumes a 12-bit ADC, where the full-scale ADC count is 4095. The measured current is represented in per-uni...
1 month ago | 0
Submitted
Motor Control Using NXP™ Development Kits
Field-Oriented Control of Permanent Magnet Synchronous Motor Using NXP™ Development kits
2 months ago | 1873 downloads |
Submitted
Identify-and-Validate-Optimal-Motor-Rating
This repo illustrates a workflow to use Virtual Vehicle Composer with Motor Control Blockset to identify and validate motor rati...
4 months ago | 3 downloads |
PMSM motor cannot start up when using launchpad F28379D + FOC in simulink
Run the example in open-loop control mode to validate the hardware setup and motor. The example has an open loop start-up. Modif...
9 months ago | 0
示例《Sensorless Field-Oriented Control of PMSM Using DC Shunt Current Sensing》中,仿真和代码生成的相移方向是相反的,应如何理解?
Hello, thank you for the question. Your observation is correct. Hardware configuration is for rising edge but simulation plant l...
9 months ago | 0
| accepted
Submitted
Demos for Motor Control Deployment on Renesas Controllers
PMSM control examples using the Renesas motor control development kits.
1 year ago | 298 downloads |
Sensorless Control with High Frequency Signal Injection at Low Speed
Please refer to the following document page: Initial Position Estimation and Field-Weakening Control of IPMSM Using Pulsating Hi...
1 year ago | 0
How to generate first value for Kp, Ki of PID in current controller
Please refer to the following document page: Estimate Control Gains and Use Utility Functions.
1 year ago | 1
In the BLDC motor block, a non-standard d'q' Transformation is used. Does this affect the values of L_d and L_q?
Thank you for providing your valuable feedback. The factor of π is a typographical error in the documentation and will be correc...
1 year ago | 0
Submitted
Motor Swap of PMSM Using Microchip MCS MCLV-48V-300W
Run any three-phase PMSM using Microchip MCS MCLV-48V-300W Development Board and dsPIC33AK128MC106 MC DIM
1 year ago | 56 downloads |
Submitted
Demos for Motor Control Deployment on Microchip Controllers
PMSM control examples using the Microchip motor control development kit.
2 years ago | 616 downloads |
TI F28379D Launchpad Serial Communication Failure
In mcb_param_est_host_read, update the COM port in 3 blocks, Host Serial Setup, Host Serial Receive, Host Serial Transmit. You ...
3 years ago | 0
| accepted
I want to make 'Deploying Motor Control Algorithms on Microchip dsPIC, PIC32, and SAM Controllers'. But MPLAB version is different. Could you give me the 3.50 version?
Hi, Please post a query at MPLAB Device Block page to check if it supports 3.50 version.
3 years ago | 0