Can etas inca calibration software calibrate stm32 programs developed on simulink, by using a serial device?

10 views (last 30 days)
Can etas inca calibration software calibrate stm32 programs developed on simulink, by using a serial device?
First ,I used the stm32 toolbox and used semi-physical emulation, the semi-physical emulation was via xcp on serial, and the serial chip used was a CH340, and it does work.
And then, I now want to use the generated a2l file and combine it with etas inca to calibrate the stm32 directly using a third party given calibration tool through the CH340 chip, is this method ok?
Or the xcp on serial is just simulink's own private, the third party calibration tool can't use the ch340 to support this function of xcp on serial?

Answers (1)

Saurav Shandilya
Saurav Shandilya on 13 Feb 2024
As per INCA documentation (Details - XCP-IP - ETAS), there is support for XCP on CAN and Ethernet. Therefore XCP on Serial can not be used with INCA. You can use CAN or Ethernet as physical layer if you want to use INCA for calibration.
Simulink support XCP on Serial for STM32 targets using Monitor & Tune options.
Regards
Saurav

Products


Release

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!