If i use the following saturation vector (20 elements) in the model, i get a strange saturation curve which ends at 0.55 for If
U=[0, 0.045, 0.145, 0.3, 0.54, 0.68, 0.79, 0.86, 0.92, 0.96, 1.00, 1.04, 1.09, 1.13, 1.19, 1.21, 1.23, 1.24, 1.27, 1.29]
If=[0, 0.033, 0.099, 0.20, 0.36, 0.46, 0.56, 0.66, 0.76, 0.86, 1.00, 1.17, 1.50, 1.83, 2.49, 2.82, 3.14, 3.48, 4.14, 4.79]
If i use a smaller vector I get the following saturation curve
If=[0,0.56,1,1.99,2.98,4.79]
U=[0,0.79,1,1.15,1.22,1.29]
I don't understand, why the first curve, which shoul be more accurate is almost linear because simscape stops calculating in the linaer part of the curve. The overall simulation result is also wrong, because the pu voltage is not 1 for if=1, it is somthing like 1.6