HDL IP Core generation for Xilinx Vivado fails since the year turned from 2021 to 2022

62 views (last 30 days)
Since returning to the office in 2022, I have been unable to use HDL Workflow Advisor with Xilinx Vivado. I see the following error message in HDL Workflow Advisor in Task 3.2:
Failed Task "Vivado IP Packager" unsuccessful. See log for details. Generated logfile: hdl_prj\hdlsrc\modelname\workflow_task_VivadoIPPackager.log
Error using hdlturnkey.ip.IPEmitterVivado/packageVivadoIP
Task "Vivado IP Packager" unsuccessful. See log for details.
Generated logfile: hdl_prj\hdlsrc\modelname\workflow_task_VivadoIPPackager.log
Error in hdlturnkey.ip.IPEmitterVivado/generateIPCore
Error in hdlturnkey.ip.IPDriver/generateIPCore
Error in hdlturnkey.TurnkeyDriver/makehdlturnkeycore
Error in hdlturnkey.TurnkeyDriver/makehdlturnkey
Error in slhdlcoder.HDLCoder/makehdlturnkey
Error in downstream.DownstreamIntegrationDriver/runIPCoreCodeGen
Error in generateIPCore
Error in Simulink.ModelAdvisor/executeCheckCallbackFct
Error in Simulink.ModelAdvisor/run
Error in Simulink.ModelAdvisor/runCheck
Error in ModelAdvisor.Node/runTaskAdvisor
Error in ModelAdvisor.Node.run
If I check the log at \hdl_prj\hdlsrc\modelname\workflow_task_VivadoIPPackager.log, I see the following error message:
"bad lexical cast: source type value could not be interpreted as target while executing"
Task "Vivado IP Packager" unsuccessful. See log for details.
Generated logfile:
****** Vivado v2018.3 (64-bit)
**** SW Build 2405991 on Thu Dec 6 23:38:27 MST 2018
**** IP Build 2404404 on Fri Dec 7 01:43:56 MST 2018
** Copyright 1986-2018 Xilinx, Inc. All Rights Reserved.
source vivado_ip_package.tcl -notrace
INFO: [IP_Flow 19-234] Refreshing IP repositories
INFO: [IP_Flow 19-1700] Loaded user IP repository 'c:/Users/Li/Desktop/Mankov/hdl_prj/ipcore'.
WARNING: [IP_Flow 19-3656] If you move the project, the path for repository 'c:/Users/Li/Desktop/Mankov/hdl_prj/ipcore' may become invalid. A better location for the repository would be in a path adjacent to the project. (Current project location is 'c:/Users/Li/Desktop/Mankov/hdl_prj/ipcore/DUT_IO33x_IP_v1_0/prj_ip'.)
INFO: [IP_Flow 19-2313] Loaded Vivado IP repository 'C:/Xilinx/Vivado/2018.3/data/ip'.
INFO: [IP_Flow 19-5107] Inferred bus interface 'DMA_Stream_FPGA_to_CPU_Master' of definition 'xilinx.com:interface:axis:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'AXI4_Lite' of definition 'xilinx.com:interface:aximm:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'AXI4_Lite_ARESETN' of definition 'xilinx.com:signal:reset:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'IPCORE_RESETN' of definition 'xilinx.com:signal:reset:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'AXI4_Lite_ACLK' of definition 'xilinx.com:signal:clock:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'IPCORE_CLK' of definition 'xilinx.com:signal:clock:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-4728] Bus Interface 'AXI4_Lite_ARESETN': Added interface parameter 'POLARITY' with value 'ACTIVE_LOW'.
INFO: [IP_Flow 19-4728] Bus Interface 'IPCORE_RESETN': Added interface parameter 'POLARITY' with value 'ACTIVE_LOW'.
INFO: [IP_Flow 19-4728] Bus Interface 'AXI4_Lite_ACLK': Added interface parameter 'ASSOCIATED_BUSIF' with value 'AXI4_Lite'.
INFO: [IP_Flow 19-4728] Bus Interface 'AXI4_Lite_ACLK': Added interface parameter 'ASSOCIATED_RESET' with value 'AXI4_Lite_ARESETN'.
INFO: [IP_Flow 19-4728] Bus Interface 'IPCORE_CLK': Added interface parameter 'ASSOCIATED_RESET' with value 'IPCORE_RESETN'.
WARNING: [IP_Flow 19-3158] Bus Interface 'DMA_Stream_FPGA_to_CPU_Master': FREQ_HZ bus parameter missing from AXI interface when interface is not associated to a clock.
WARNING: [IP_Flow 19-3153] Bus Interface 'IPCORE_CLK': ASSOCIATED_BUSIF bus parameter is missing.
INFO: [IP_Flow 19-2181] Payment Required is not set for this core.
INFO: [IP_Flow 19-2187] The Product Guide file is missing.
bad lexical cast: source type value could not be interpreted as target
while executing"rdi::set_property core_revision 2201031458 {component component_1}"
invoked from within
"set_property core_revision 2201031458 [ipx::current_core]"
(file "vivado_ip_package.tcl" line 57)
INFO: [Common 17-206] Exiting Vivado at Mon Jan 3 14:58:23 2022...
Elapsed time is 12.568 seconds.

Accepted Answer

MathWorks HDL Coder Team
MathWorks HDL Coder Team on 4 Jan 2022
Edited: Stefanie Schwarz on 10 Jan 2022
Refer to the following External Bug Report for a resolution to this issue:
Note: You will need to login to your MathWorks account to access this link.
  6 Comments

Sign in to comment.

More Answers (1)

Kiran Kintali
Kiran Kintali on 19 Jan 2022
Edited: Kiran Kintali on 19 Jan 2022
Posting this again here for more visibility into this issue and proposed fix for HDL Coder Xilinx IP Core Workflow.
To fix the issue with HDL Coder please apply the patch in the above link.
  3 Comments
Kiran Kintali
Kiran Kintali on 27 Apr 2022
Yes, the patch does not exist for 15b. See fix releases here.
Please contact MathWorks technical support for guidance on 15b release.

Sign in to comment.